Easy operation with UP/DOWN key
High Resolution: 10mV, 1mA
Over voltage protection, over current protection by hardware
50 Sets memory
Self test and software calibration
Meets UL CSA IEC Safety Regulation
Auto Step Running With Timer Setting
FRONT/REAR Output and Sense Switch Selectable
Triple Output
Auto Series and Parallel Operation
Auto Tracking
IEEE-488.2 and SCPI Compatible Command set
Labview Driver Software Available
High Stability, Low Drift
4 Digit Display
PPT-1830 | PPT-3615 | |
OUTPUT | ||
Voltage | 0~18Vx2, 0~6Vx1 | 0~36Vx2, 0~6Vx1 |
Current | 0~3Ax2, 0~5Ax1 | 0~1.5Ax2, 0~3Ax1 |
OVP | 0~20Vx2, 0~7Vx1 | 0~38.5Vx2, 0~7Vx1 |
LOAD REGULATION | ||
Voltage | < 3mV rear output ( < 6mV front output ) | |
Current | < 3mA ( < 6mA rating current > 3.5A ) | |
LINE REGULATION | ||
Voltage | < 3mV | |
Current | < 3mA | |
RESOLUTION | ||
Voltage | 10mV ( 20mV rating voltage > 36V ) | |
Current | 1mA ( 2mA rating current >3.5A ) | |
OVP | 10mV( 20mV rating voltage > 36V ) | |
PROGRAM ACCURACY (25±5° C) | ||
Voltage | < 0.05% + 25mV ( + 50mV rating voltage > 36 V ) | |
Current | < 0.2% + 10mA | |
OVP | < 2% + 0.6V | |
RIPPLE & NOISE (20Hz ~ 20MHz) | ||
Voltage | Ripple 1mVrms / 3mVp-p Noise 2mVrms / 30mVp-p | |
Current | < 3mA rms ( < 5mA rms rating current > 3.5A ) | |
TEMPERATURE (0~40° C ) COEFFICIENT | ||
Voltage | < 100ppm + 3mV | |
Current | < 150ppm + 3mA | |
READBACK RESOLUTION | ||
Voltage | 10mV ( 20mV rating voltage > 36V ) | |
Current | 1mA ( 2mA rating current > 3.5A ) | |
READBACK ACCURACY (25±5° C) | ||
Voltage | < 0.05% + 25mV ( + 50mV rating voltage > 36V ) | |
Current | < 0.2% + 10mA | |
RESPONSE TIME | ||
Voltage Up(10%~90%) | < 100mS | |
Voltage Down(90%~10%) | < 100mS (≧ rating road) | |
READBACK TEMPERATURE COEFFICIENT | ||
Voltage | < 100ppm + 10mV ( + 20mV rating voltage > 36V ) | |
Current | < 150ppm + 10mA | |
DRIFT | ||
Voltage | < 0.03% + 6mV | |
Current | < 0.1% + 6mA | |
TRACK OPERATION | ||
Tracking Error | < 0.1% + 50mV | |
Series Regulation | < 50mV | |
PARALLEL OPERATION | ||
Program Accuracy (25±5° C) | Voltage < 0.05% + 25mV ( + 50mV rating voltage > 36V ) Current < 0.2% + 20mA OVP < 2% + 0.6V | |
Load Effect | Voltage < 3mV rear output ( < 6mV front output ) Current < 6mA ( < 12mA rating current > 3.5A ) | |
Source Effect | Voltage < 3mV Current < 6mA | |
MEMORY | ||
Store / Recall 50 sets | ||
TIMER | ||
Setting time | 1 sec ~ 255 min ( Max 255 min x 50 sets) | |
Resolution | 1 sec | |
Function | for output working loop ( Auto Step Running) | |
INTERFACE | ||
GPIB | ||
POWER SOURCE | ||
AC100V/120V/220V/240V±10%, 50/60Hz | ||
DIMENSIONS & WEIGHT | ||
255(W) x 145(H) x 346(D)mm Approx. 10 kg |